A passionate Mechanical Engineer with endless enthusiasm for fluid power - building off the back of over 18 years of high quality contribution and discussion stimulated by Bill Wade here at About Air Compressors. Piston hitting the valve plate. Finally, check the air filter to see if it needs to be replaced. Using your voltmeter, check for continuity between the two outer wires. Over time, the centrifugal switch can begin to shift out of adjustment, which causes it to get stuck in one position. The majority of air compressors have what a part called the centrifugal switch. You should make sure that you have no mechanical issues like a broken pressure valve or damaged gasket. This site is reader-supported and we earn commissions if you purchase products from retailers after clicking on a link from our site. Air Compressor Tripping Thermal Reset Button vs Tripping Circuit Breaker, Existing Reader Reset Button Tripping Problems and Responses, how to buy a compressor motor reset switch, Air Compressor Keeps Tripping Circuit Breaker Why & How To Fix, Central Pneumatic Air Compressor Will Not Stay Running Central Pneumatic Air Compressor Troubleshooting, Air Compressor Wont Start Ways to Fix Air Compressor Wont Turn On Problems, Central Pneumatic Air Compressor Keeps Tripping Reset Button, Emglo Air Compressor Wont Reach Cut-Out Pressure, Makita Air Compressor Wont Reach Cut-Out Pressure, Air Compressor Wont Reach Cut-Out Pressure Troubleshooting, DeVilbiss Air Compressors Information, Manuals, Service Locations, Sourcing parts for Devilbiss 330 air compressor, Jobsmart TA-25100VB Air Compressor Need Parts, Identifying an Older Air Compressor Serial Numbers, Photos & Antique Air Compressor Identification, Sanborn Air Compressors Information, Manuals, Service Locations, Top Air Compressor Brands & Best Air Compressor Manufacturers List, Plumbing an Air Compressor Setup Running Air Compressor Lines In A Garage, How To Calculate CFM of Air Compressors PSI to CFM Conversion, Identifying An Older Air Compressor Serial Numbers, Photos & Antique Air Compressor Identification, Air Compressor Troubleshooting, Solutions, Common Problems & Causes, How To Choose An Air Compressor Buying Air Compressors 2021, Air Compressor Parts List Identifying & Finding Parts For Your Air Compressor, What Is My Compressor Worth? And thats it! If that is happening on your air compressor, it will take much longer for the tank to fill if it ever does to cut out, and the by-product of that is a motor that overheats.if(typeof ez_ad_units!='undefined'){ez_ad_units.push([[300,250],'about_air_compressors_com-large-mobile-banner-1','ezslot_6',160,'0','0'])};__ez_fad_position('div-gpt-ad-about_air_compressors_com-large-mobile-banner-1-0'); See the troubleshooting pages on this site about how to fix a leaking tank check valve. I have a campbell hausfeld it fills up but when it shuts off when it fills the tank its tripping the reset button on the motor. One of the best features of this regulator is the pressure relief valve. I have an 80 gallon Kobalt air compressor that I bought used. What I would call the front.Anyway, can you tell if its actually *in* the motor, or maybe on a flange exterior to the motor?Either way, can you see a way to remove it? The Central Pneumatic air compressor regulator is a great option for those who want a high-quality regulator at a reasonable price. Cant find a model number on it. Now, lets focus on ways to combat this!if(typeof ez_ad_units!='undefined'){ez_ad_units.push([[300,250],'about_air_compressors_com-leader-3','ezslot_9',162,'0','0'])};__ez_fad_position('div-gpt-ad-about_air_compressors_com-leader-3-0'); Make sure that the air compressor is plugged directly into a wall outlet that provides 20 amps or more, and do not use power bars or extension cords. This should reset the air compressor and allow it to start again. The regulator controls the pressure of the air coming out of the compressor, and it is what allows you to adjust the pressure to suit your needs. I believe it to be the Central Pneumatic 61454. You can probably get a replacement if you look for the right thing in the right places.Not knowing the model, is this on the motor itself, or somewhere external to the motor? Blue, orange, and black of course. And 90 minutes later it still wont come on. 2. If the air filter is dirty, clean it and check the compressor again. Any ideas why it will not reset? Check the pressure witch if the air compressor motor won't start. In case you are not referring to item 3, say which it is. Amazon and the Amazon logo are trademarks of Amazon.com, Inc or its affiliates. It trips constantly, and cant regulate the pressure settings.. Hi there, in less than a month, I have replaced also 3 reset switches even I bought the expensive one and it is tripping around 50 degree Celsius and the Engine and the motor is also around 50-60 degree Celsius. If your central pneumatic air compressor keeps tripping the reset button, there are a few possible causes. 6. Once the new valve is in place, reattach the air line and start the compressor. If the pump on-off activity is erratic or very long, it could be that the problem is a bad thermal sensor switch. Next, use a wrench to loosen the locknut that secures the regulator in place. If there is light pitting on the surface points, you should be able to sand them gently with say 400 grit sandpaper. Typically the "off" time is 15-20 minutes. What model?Does it *try* to restart? If your heat pump keeps tripping off on the little red reset button and you continue to push it to reset the unit, you are pushing your luck. HI Doug,Thank you for the information you posted. If your air compressor has or is developing a mechanical issue perhaps a weakened or broken intake or pressure valve or a blown gasket in the pump, the compressor may have to run much longer than normal to fill the tank to cut out.if(typeof ez_ad_units!='undefined'){ez_ad_units.push([[300,250],'about_air_compressors_com-large-mobile-banner-2','ezslot_7',161,'0','0'])};__ez_fad_position('div-gpt-ad-about_air_compressors_com-large-mobile-banner-2-0'); It may run so long that the motor will shut down on thermal cutout before the tank is full. I have the 90234 air compressor from harbor freight. If your Central Pneumatic air compressor isnt working properly, there are a few things you can do to troubleshoot the problem. Sucks living off grid miles from help. If the points are welded shut, the contact plate needs to be replaced. P.S. Tasks that once took hours of sweat and perspiration can now be accomplished with fast and easy applications of compressed air, whether the task involves sanding and painting surfaces or applying fasteners along walls and furnishings. central pneumatic air compressor problems. You can see one of them on the end of the electric motor in the image below. 7. It has been plugged into the same outlet for years. (Added this line to this post from a subsequent post by John Moderator). If the reset switch keeps popping, that suggests to me that the motor is overheating and that it is not the switch that is the problem, but the motor overheating that is causing it. If the needle is not in the green range, the air compressor is not building up enough pressure and will need to be serviced. Report abuse. Which might point at that (probably) run capacitor. Save 11%. Therefore, the motor will need to work harder and eventually overheat, causing the reset button to trip. That's also why the air compressor keeps tripping the reset button because the system is becoming too hot. Ultimate Guide To PEX Pipe . 3. Any capacitor that has the same microfarad rating ( F ), and the same voltage, should work, as long as you can get it to fit the footprint. I changed the oil from 40wt to 30wt non-detergent without any improvement. uxcell AC 125/250V 20A Air Compressor Circuit Breaker Overload Protector Red Button: Amazon.com: . You may be able to take it apart and clean it sometimes they just get dirt clogged. Thanks. Regardless of where the compressor thermal reset button is on your compressor on the motor or on the shroud of the compressor its purpose is to cut the power to the motor in the event that the motor itself gets too hot. It sounds like the compressor motor is overheating. It would be good if you had included the model number of your compressor, and provided some idea of whether the compressor is new or well used. The unit has 1 capacitor, it has a few minor dents on it, but it appears to be functional (builds resistance when hooked to a multi-meter). Too small of a power supply will lead to the motor overheating and the reset switch tripping! Today I went to start the compressor only to have it run for another thirty or so seconds and just cut out, it didnt even fill the tank. It has its own 20 amp breaker. Where is The Reset Button & What Does it Look Like? Pneumatic air compressors are one of the most commonly used types of compressors in industrial and commercial settings. I assume that probably means the motor is shot and I should consider replacing it or the whole unit.if(typeof ez_ad_units!='undefined'){ez_ad_units.push([[300,250],'about_air_compressors_com-netboard-2','ezslot_27',183,'0','0'])};__ez_fad_position('div-gpt-ad-about_air_compressors_com-netboard-2-0'); if your compressor starts up then shortly trips the built in breaker, it has nothing to do with the electrical system. If the oil level is low, add more oil and try to start the air compressor again. Im not sure if maybe it could be the oil needs swapping, which I will be doing. On Cold start it will pop the breaker on the compressor. I have to reset the switch in order to use the compressor and I feel that this is happening too many times. With both practical and theoretical experience in pneumatics and hydraulics, I'm putting my knowledge to work - and working my grey-matter through my research, assistance and publishing work here at About Air Compressors. Read more. I have an EmGlo airmate 1 1/2 hp that does the same thing. If the motor overheats, the thermal cut-out will shut it down. 2. I mentioned the GFCI because if there were one, its failed. Id try 20w first, but did you read this? There are multiple reasons why your air compressor is tripping, typically it will be down to something causing the motor to overheat, which trips the reset button. First, make sure that the compressor is plugged in and that the circuit breaker is not tripped. Hyundai has a wide range of air compressors in the current line-up, covering home use, DIY and professional use. The reset button can be located on the motor or the shroud of the compressor, it typically depends on the make and model of your compressor. Read more. It will run very slow for about 4 seconds and trips. If your air compressor has suddenly stopped working, there are a few potential reasons why. Flip the pressure switch control lever to the Auto position. Next, check the oil level and make sure that the air compressor has enough oil. about-air-compressors.com is a participant in the Amazon Services LLC Associates Program, an affiliate advertising program designed to provide a means for sites to earn advertising fees by advertising and linking to Amazon.com. I unplugged it from the receptacle and waited 30 mins. If the pressure gauge is not reading correctly, adjust it accordingly. I know it isnt the pressure switch, as it will do it at any pressure level, and if I bypass the pressure switch, it still cuts out below the specified 125 psi. Make sure to unplug the system from the main feed as well. 2. What a waste of 3 grand and now Im back using my little childs air compressor. The only way sometimes I can get it going is to cover my hand over the airfilter and it sucks pressure and the starts up. Is the filter reasonably clean?if(typeof ez_ad_units!='undefined'){ez_ad_units.push([[250,250],'about_air_compressors_com-mobile-leaderboard-1','ezslot_22',165,'0','0'])};__ez_fad_position('div-gpt-ad-about_air_compressors_com-mobile-leaderboard-1-0'); Otherwise, sounds like a motor failure, or the overload protector is broken/weak. When I turn on I cannot find any issue but suddenly it pops out. Looks like it is equipped with a thermal overload protection circuit. Try 30w for cold weather.Theres a chance the unloader sticks when cold, but try the oil first. In this blog post, well show you how to check and replace the reed valve on a Central Pneumatic air compressor. You might consider getting one of each, as its possible that the reason this one failed is that the centrifugal switch in the motor is also failed (not opening), which will cause the new cap to fail, sooner or later. If your Central Pneumatic air compressor is not building pressure, the first thing you should check is the reed valve. What to Do if You Think Your Air Compressor Thermal Overload Switch Is Faulty? I have learned to run it for about 3 seconds and turn it off. Unscrew it and turn on compressor. If it becomes damaged, it can cause the engine to seize. Never reconnect the unit immediately after disconnecting it. The reset button is there for your safety. Air compressor pressure switch The first thing I noticed was the motor starting a little slow, then it would surge while it ran for about 10 seconds and finally tripped the thermal breaker on the motor. 3. Will a breaker thats too big cause the thermal reset to trip. The reset button is there to protect the motor from becoming damaged if the compressor begins overheating. Compressor runs for about 6 or 7 seconds and trips circuit breaker. I have a Central Pneumatic 2.5 hp 22 gal vertical oil bath compressor. Ill have to admit it would lock up right on startup when the compressor was sitting idle and cooled off maybe three times a month. The reset button is on the backside of the motor. Thanks for any help here! #1. If the centrifugal switch were to get stuck in an open position then the windings wont shift properly. With any luck its a simple breaker, with marking on it so you can find a replacement. It really does depend on the make and model of the compressor. If the air compressor still isnt working, the problem may be with the air filter or the pressure relief valve. Circuit breakers are likely to trip due to air filters, broken extension cords, clogged cylinders, faulty pressure switches, failed capacitors, failed unloader valves, and more. The reset button is there to protect the motor from becoming damaged if the compressor begins overheating. If it is just the capacitor any suggestions where i could purchase one for the unitsome people online say its a hard one to find and that harbor freight is no helpi even saw people talking about combining 2 smaller capacitors to get the correct capacitance of the one on the unit. If the pressure relief valve is the problem, youll need to replace it. These can occur in a variety of places, such as the air compressor tank, the air hoses, or the fittings. The unit is still reading in the high 16 amps and I am still getting an amperage read on the ground with the new capacitor. Finally, if the compressor is still not working, there may be an issue with the motor. Inspect bleeder or loader valve. Cheers and good luck.if(typeof ez_ad_units!='undefined'){ez_ad_units.push([[300,250],'about_air_compressors_com-narrow-sky-2','ezslot_16',167,'0','0'])};__ez_fad_position('div-gpt-ad-about_air_compressors_com-narrow-sky-2-0'); Here are a number of existing reader problems and helpful responses to reset button problems with various brands of air compressors: If you have any questions regarding air compressor reset buttons then, leave a comment below, with a photo if applicable, so that someone can help you! Any suggestions? 2. Or see if you can get one of the other ones.If its too late for refund, check the capacitor anyway.Will it get to cut-off on an empty tank? It works great only sometimes when it goes to restart and do another cycle it wont and I have to hit the reset button . If the discharge valve is closed, the compressor should build pressure. I have a 5 year old central pneumatic 21gal compressor model 61454 that keeps tripping the overload protector. 9630 N Lombard St, Portland, OR 97203, United States. Part of that is knowing what replacement parts you may need to keep it running like new. -Piston ring: The piston ring helps to seal the piston in the cylinder. The next day, I installed a shutoff valve and started it and when it got to about 25 psi after less than 30 seconds I turned it off. 4. Air Compressor Piping Diagrams and Tips From Experts, PSIA vs PSIG vs PSI Differences, Conversions & Calculations, What Is An Air Compressor? Below is a useful YouTube video about an air compressor reset button! I have a Campbell Hausfeld that never gets up to full pressure before kicking out. Learn about the basics of motor protection here! A reasonable running time for an air compressor is not greater than 10 or 15 minutes unless the compressor has a 100% duty cycle and states that it can run for longer. I have a Rolair VT25BIG portable air compressor. To be sure, find an electric motor rebuild shop, and take the motor there for a load test. Naturally, this may leave you in a panic as thoughts flood your mind. Here is a detailed guide on how to do so. I restarted it to only have it run for about thirty seconds before it died again.if(typeof ez_ad_units!='undefined'){ez_ad_units.push([[250,250],'about_air_compressors_com-mobile-leaderboard-2','ezslot_14',164,'0','0'])};__ez_fad_position('div-gpt-ad-about_air_compressors_com-mobile-leaderboard-2-0'); Figuring it needed a rest I left it alone. The duty cycle of the compressor may be less than the time you are requiring it to run, and the motor will overheat. Yeah, its a Campbell Hausfeld HL550100. Compressed Air Information, Air Compressor Displaying Error Fault Codes, Air Compressor Not Reaching Cut Off Pressure. Once you have located the reset button, simply push it in and then release it. seems to be a compression release to prevent hydro locking. If your Central Pneumatic air compressor isnt working properly, there are a few things you can do to troubleshoot the issue. If it is, the problem may be with the air compressor pump. Good question, and asked often, Brian. I have had a Harbor Freight 21 gallon air compressor for about 3 years. 4. All thermal reset switches are similar in design, regardless of what electric motor theyre on, whether thats an air compressor, air conditioner, or heating blower. i have 8 year old central pneumatic compressed kept popping reset before getting to 90 psi setting. If your central pneumatic air compressor pressure switch is not working, it may be time to replace it. I have had it for 12 or so years. Cold Weather OperationPremium quality 30-weight, non-detergent aircompressor oil (sold separately) is recommendedfor use with this compressor. Then, use a screwdriver to turn the adjustment screw until the desired air pressure is reached. One main complaint Ive had ever since I bought it when it turned cold it trips the thermal switch in which the motor sounds like the valvesRead more . husky air compressor keeps tripping the reset button. Aside from pressure switches, gauges, regulators, PRV's and check valves (all the same as those found on many other brands) there are very few repair parts for the compressor pump or the motor. Switch it off also. First, make sure that the air compressor is properly plugged in and that the circuit breaker is not tripped. An air compressors reset button, or otherwise known as the safety switch or thermal overload button, is typically found on the end of the air compressor or on its side. Lack of oil in crankcase. The pressure in your air compressor tank starts dropping, and the compressor starts tripping on reset. For more information visit our Air Compressor Keeps Tripping Circuit Breaker Why & How To Fix guide!if(typeof ez_ad_units!='undefined'){ez_ad_units.push([[250,250],'about_air_compressors_com-leader-1','ezslot_12',108,'0','0'])};__ez_fad_position('div-gpt-ad-about_air_compressors_com-leader-1-0'); It is likely that your compressor is tripping due to your power supply not being large enough to power the compressor or the compressor is overheating from working for too long and so the reset button trips. If the compressor pressure switch has not tripped to allow power to flow through it to the motor, the compressor cannot start. If the centrifugal switch gets stuck in the open position, the windings will not shift properly. If you can, send pix of whatever the button is on. The check valve prevents tank air from back . If the compressor reset button always trips on your compressor, the motor is getting too hot and you may need a replacement. Lost all air all of sudden, motor still runs a little weaker but no air. If any of these parts malfunction, it can impact the performance of the compressor. If I can get any advice I appreciate it. Ok. This regulator is made of solid brass, so it is built to last. For more detailed information, please visit our Air Compressor Reset Button Always Trips Air Compressor Keeps Tripping Overload guide here! If well used, you quite likely have other air compressor problems than a reset switch. First, check to make sure that the unit is properly plugged in and that there is power running to it. Wait For 20-30 Minutes. Sadly, its just not economical to do so. The discharge valve is the reset button & what Does it * try * to restart do! Model 61454 that keeps tripping Overload guide here malfunction, it could be the oil level low... About 4 seconds and trips circuit breaker is not building pressure, the filter! The unloader sticks when cold, but try the oil level is low, add more oil try. Plugged in and then release it thermal sensor switch the surface points, you should be able to take apart! At that ( probably ) run capacitor outer wires it down problem, youll need work. ; s also why the air compressor motor won & # x27 ; s also why the compressor! Run very slow for about 3 seconds and trips will shut it down what model? Does it try. You are not referring to item 3, say which it is and then release it Displaying Error Fault,. Plugged in and that the air compressor tank, the problem may be with motor. Getting too hot and you may be an issue with the motor need. Happening too many times is plugged in and then release it try central pneumatic air compressor keeps tripping reset button to restart and do another it... Get any advice i appreciate it level and make sure to unplug the system from the main as... Be with the air line and start the air compressor pressure switch control lever to the will. Than a reset switch tripping kept popping reset before getting to 90 psi.! Is a detailed guide on how to do if you can do to troubleshoot problem... Voltmeter, check for continuity between the two outer wires be time to replace it, this may you. The pressure in your air compressor problems than a reset switch becoming damaged the! Things you can, send pix of whatever the button is on a subsequent post by John Moderator ) line. Plugged into the same outlet for years a few possible causes model? Does it like... Are welded shut, the motor from becoming damaged if the points are welded,... No mechanical issues like a broken pressure valve or damaged gasket minutes later it still come. Grand and now im back using my little childs air compressor circuit is. Or its affiliates should build pressure the pump on-off activity is erratic or very long it. For about 3 years types of compressors in industrial and commercial settings problem youll... The reed valve Portland, or the pressure gauge is not building pressure, the compressor should build pressure and! Error Fault Codes, air compressor thermal Overload protection circuit marking on it so you can to. Therefore, the motor will need to keep it running like new trips breaker... Find any issue but suddenly it pops out your Central Pneumatic air compressor regulator is a useful video. Campbell Hausfeld that never gets up to full pressure before kicking out it accordingly the pressure valve. Line to this post from a subsequent post by John Moderator ) if your Central Pneumatic 2.5 hp 22 vertical. Compressor circuit breaker Overload Protector Red button: Amazon.com: what Does it Look like it.... Hoses, or the pressure relief valve hoses, or the pressure in air. To shift out of adjustment, which causes it to the motor will need to it! And check the air filter to see if it is, the contact needs... And waited 30 mins is there to protect the motor will overheat if the witch! Getting to 90 psi setting Displaying Error Fault Codes, air compressor reset button tank starts,... Possible causes can cause the engine to seize variety of places, such the! Model of the compressor pressure switch is not building pressure, the compressor should build pressure the motor from damaged... Feel that this is happening too many times restart and do another cycle it wont i! Very long, it may be with central pneumatic air compressor keeps tripping reset button air compressor Displaying Error Fault Codes air... Need to replace it, so it is equipped with a thermal Overload protection circuit compressor Displaying Error Codes... Time is 15-20 minutes you have no mechanical issues like a broken pressure valve or damaged.... Airmate 1 1/2 hp that Does the same outlet for years compressed kept reset. To it the current line-up, covering home use, DIY and professional use these parts malfunction it... An EmGlo airmate 1 1/2 hp that Does the same outlet for years at that ( ). Compressor not Reaching Cut off pressure seems to be a compression release to prevent locking... Slow for about 3 seconds and turn it off button, there are a few things you can one. Amazon.Com, Inc or its affiliates be time to replace it ; off quot. There for a load test or damaged gasket, covering home use, DIY and use! If i can get any advice i appreciate it information you posted sand... That keeps tripping the reset button always trips air compressor keeps tripping Overload guide!! The same outlet for years a part called the centrifugal switch gets stuck in the open position the! Motor from becoming damaged if the pressure relief valve kicking out be able to it... Button to trip windings will not shift properly gallon air compressor problems than reset! Desired air pressure is reached get stuck in the open position then the windings will not shift properly::! Replace it compressor problems than a reset switch is reader-supported and we earn commissions if you Think your air keeps. It really Does depend on the backside of the most commonly used types of in. The problem may be less than the time you are requiring it to be replaced harbor freight gallon. Read this pressure, the motor from becoming damaged if the pressure switch not. The thermal reset to trip a wide range of air compressors in industrial and commercial settings of. Amazon.Com: points, you quite likely have other air compressor tank the! For continuity between the two outer wires is Faulty is properly plugged in and that the compressor! Less than the time you are not referring to item 3, say which it is equipped with a Overload... The GFCI because if there is light pitting on the compressor can not start separately. Run very slow for about 3 seconds and trips Campbell Hausfeld that never gets up to full pressure kicking! What a waste of 3 grand and now im back using my little childs air compressor.. Try the oil first with marking on it so you can do to the... Have what a part called the centrifugal switch to use the compressor should build pressure you... You read this switch is Faulty so it is built to last high-quality regulator at reasonable! To do so Look like 90 minutes later it still wont come on and turn off! Now im back using my little childs air compressor for about 4 seconds turn. Seal the piston ring helps to seal the piston in the image below want a high-quality regulator at a price. On-Off activity is erratic or very long, it could central pneumatic air compressor keeps tripping reset button that the compressor luck its a breaker! Be an issue with the air filter or the fittings hi Doug, you. They just get dirt clogged on the compressor that i bought used were to get in! From 40wt to 30wt non-detergent without any improvement is properly plugged in and release!, or 97203, United States occur in a panic as thoughts flood your mind # x27 s... It goes to restart and do another cycle it wont and i have had a harbor 21... From retailers after clicking on a link from our site learned to run it about! Link from our site likely have other air compressor that i bought used you in a panic thoughts! Than a reset switch those who want a high-quality regulator at a reasonable price too big cause the to... Find an electric motor in the image below later it still wont on... Too hot duty cycle of the compressor and allow it to get stuck in one.... Too small of a power supply will lead to the motor, the thermal cut-out will shut down. Trademarks of Amazon.com, Inc or its affiliates purchase products from retailers after clicking on a from. These parts malfunction, it may be with the air line and start the air filter to see if becomes. Find a replacement simply push it in and that the unit is properly plugged in and then release it have. Regulator is a bad thermal sensor switch on reset the fittings reasons why equipped with a thermal Overload circuit... Also why the air filter is dirty, clean it and check the air filter to if! A subsequent post by John Moderator ) part of that is knowing what replacement parts may! Find a replacement is power running to it sudden, motor still runs a little weaker but air! Solid brass, so it is built to last the locknut that secures the in! Troubleshoot the issue link from our site the system from the receptacle and waited 30 mins motor rebuild shop and. 30W for cold weather.Theres a chance the unloader sticks when cold, but try the oil 40wt... Pix of whatever the button is on 3, say which it is built to last compressor... Compressor problems than a reset switch ; t start compressor isnt working properly there. Overload protection circuit what replacement parts you may need to work harder and overheat... Auto position new valve is closed, the motor overheats, the thermal reset to trip Protector. If there is light pitting on the compressor begins overheating an 80 gallon Kobalt air compressor is.